M13. Dynamic Poise
What It Is
The Dynamic Poise pane (chapter 20b) makes two fits over the upright positions, and keeps them apart:
- The measured wave, a fact: how the rate moves once round as the watch turns in its own plane, its size and its fastest hour.
- The heavy spot, an inference: which way the balance’s heavy side hangs, worked out from that wave and each position’s amplitude.
Both are core’s poise::fit.
The Angle
Each upright position is named by the hour mark at the top, and its angle
α is measured clockwise from 12H: 12H is 0°, 1H30 45°, 3H 90°, 6H 180°,
9H 270°, and so on. The angle a fit gives is turned back into the nearest
such hour for the words (“nearest 3H at the top”).
The Measured Wave
rate(α) = m + A × cos(α − φ)
mis the mean rate,Athe size of the wave each way from the mean (half its peak to peak), andφthe angle at which the watch ran fastest.- It is fitted by least squares as
m + a × cos α + b × sin α, soA = √(a² + b²)andφ = atan2(b, a). Three unknowns: three positions fix it, and the pane draws it from five, leaving two to check its shape. - Weights: each position by 1 / SE², its rate’s standard error
squared (M7), so a noisy position counts for less. The ± of
Acomes from the fit’s covariance. The ± ofφis found by test inversion: the fit’s error across the true direction is the same whateverAis, so the 95% half-width isasin(1.96 × σ⊥ ÷ A), shown as one standard error (divided by 1.96). A small wave gives a wide angle. With any position lacking a ±, the fit is unweighted and gives none. - Clear of the noise: the fastest hour is named only when
Ais at least 2 standard errors from zero. Otherwise the line says the wave is “not clear of the noise”, and names no hour.
The twice-round check. Beside the wave, the fit adds cos 2α, where
the positions leave room for a fourth unknown, and sin 2α where they
leave room for a fifth (at 90° steps sin 2α is zero at every position,
so only a 45° test gives it). These are no part of the answer. Poise
gives only the once-round wave; pivots and the hairspring can give a
twice-round one, so a large twice-round term says the wave isn’t all
poise. Info gives both, in s/d.
The Heavy Spot
A heavy spot of size U (in s/d, as a small swing would show it), lowest
at rest with angle ψ at the top, moves the rate by
U × f(θ) × cos(α − ψ), f(θ) = 2 × J1(θ) ÷ θ
where θ is that position’s amplitude in radians and J1 is the Bessel
function of the first kind, order one. f says how much of a small
swing’s poise effect is left at amplitude θ:
| Amplitude | f(θ) |
|---|---|
| 90° | 0.72 |
| 180° | 0.18 |
| 200° | 0.08 |
| 219.5° | 0 |
| 230° | −0.036 |
| 250° | −0.088 |
| 270° | −0.12 |
| 300° | −0.13 |
So the same heavy spot makes the watch fastest with it at the bottom
below 219.5°, and slowest above it; at 219.5° (3.8317 radians, the first
zero of J1) poise doesn’t move the rate at all, and near it barely.
- The fit:
m + c × f(θᵢ) cos αᵢ + d × f(θᵢ) sin αᵢ, with each position’s own amplitudeθᵢ, weighted as the wave is. ThenU = √(c² + d²)andψ = atan2(d, c): the line reads “Heavy spot hangs lowest with 4H30 at the top (…°)”, with the ± ofψ. - The amplitude’s own noise moves
f(θᵢ). Its share,U × f′(θᵢ) × SEθᵢ × cos(αᵢ − ψ), is added to each position’s rate ± from a first fit, and the fit is made once more. - It rests on the lift angle. Amplitude is worked out with the lift
angle (M4), so a lift angle set wrong moves every
θᵢ, andfwith them. - Stated only when
Uis clear of zero by 2 standard errors.
The Band Near 219.5°
The heavy spot isn’t stated when any position’s amplitude may be near 219.5°: when the range from 2 standard errors below its amplitude to 2 above, widened by 8% of the amplitude either way, holds 219.5°. With no ± that is from about 203° to 239°.
The 8% is for the lift angle. A catalogue lift angle can be several
percent out, and amplitude scales with it: the one lift angle measured
for this project moved 7.3%, from 55° to 59°. Across 219.5° the sign of
f flips, so an amplitude carried across it by a wrong lift angle would
turn the heavy spot round.
Inside the band only the measured wave is shown. Run the test where the amplitude is well away from it: let down below 203°, or fully wound above 239°.
Amplitude Round the Dial
A heavy spot barely changes the amplitude; friction, which differs by position, does. If the amplitude itself has a once-round wave, the watch’s isochronism (M12) turns it into a once-round wave in the rate too, in the same pattern as poise.
So the amplitudes are fitted with the same once-round wave. Where its size is clear of zero by 2 standard errors, the line says so: “Amplitude also changes once round, … each way, so part of the wave may be isochronism.” The pane does not take the isochronism off the rates.
Why This Way
- Two fits, not one: the fastest hour needs nothing but the rates,
so it is a fact. The heavy spot needs the amplitude, the lift angle and
the sign of
f, so it is an inference, and is withheld where those can’t settle it. - Each position’s own amplitude: in a long test the amplitude falls,
and positions differ. One amplitude for all would put the wrong
fon most of them.
What It Can’t Tell You
- A mass.
Uis in s/d, as a small swing would show it, not in milligrams. - The heavy spot near 219.5°, or where the wave is within its noise.
- Effects that look like poise: a once-round wave in the amplitude, through isochronism, is named but not taken off.
Previous: M12. Isochronism and Rate against Amplitude · Contents